Dil ID: 9
Dil Adı: germany
Dil Kodu: de9tayfun Produkte der Marke CES
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



Connect Systems Inc. - Model 9800 Page 20
If a signaling option is installed, the user now has the ability
to change the signaling mode.
Note: When selecting CTCSS signaling, it is important to remove
R8 from the unit. It may also be necessary to re-adjust
signaling levels when changing modes.
4.4. CTCSS Beep Alert (CTCSS selected on line 4.3.)
Select 3-9 (3-9 beeps)
DEFAULT: 6 = 6 Beeps
Select the number of alerting beeps that accompany the selected
CTCSS tone for selective calling. See Table 2 for CTCSS selective
call codes.
4.5. Two Tone Group Call or Diagonal Tone (Two Tone selected)
1 = Group Call
0 = Diagonal
DEFAULT: 1 = Group Call
Note: See Table 3 for Two Tone selective call codes.
4.6. Five Tone Preamble (Five Six tone selected on line 4.3.)
1 = Enable [4.7.]
0 = Disable [4.8.]
DEFAULT: 0 = Disable
Select the selective call code and all appropriate 5/6 tone
parameters from Table 4.
4.7. Preamble Tone
Select tone 0-9
DEFAULT: 0 = Tone 0
4.8. First Tone Select
Select tone 0-9
DEFAULT: 0 = Tone 0
4.9. Second Tone Select
Select tone 0-9
DEFAULT: 0 = Tone 0
5.0. Repeat Sequence
Select 1-9 (Repeat the tone sequence 1-9 times)
DEFAULT: 1 = Once
5.1. Duration of Tones
Select 1-99 (1-99 ms)
DEFAULT: 33 = 33 ms
5.2. Tone Group Select
1 = EIA
2 = ZVEI1
3 = CCIR/EEA
4 = CCIT
5 = EURO
6 = ZVEI2
DEFAULT: 1 = EIA (See Table 4)