Connect Systems Inc. - Model 9800 Page 17
2.8. CW ID
1 = CW ID at connect and disconnect.
0 = CW ID at disconnect only.
DEFAULT: 0 = At disconnect only.
After accessing, manual dialing and auto-dialing are delayed
until the CW ID is finished if you enter 1.
2.9. Automatic Busy Signal Disconnect
1 = Enable
0 = Disable
DEFAULT: 1 = Enable
3.0. Automatic Dialtone Disconnect
1 = Enable
0 = Disable
DEFAULT: 1 = Enable
3.1. Aux. Relay
0 = Connect [3.3.]
1 = Monitor [3.3.]
2 = Key [3.3.]
3 = Remote Function [3.2.]
DEFAULT: 0 = Connect
0. In connect mode, the relay is on whenever the patch is in
connect.
1. In monitor mode, the relay can only be functioned when using
Remote Base mode from a touchphone. Pressing 0 turns on the
relay. Pressing * turns it back off. The relay returns to off
automatically when Remote base operation is completed. This
function is normally used to remotely disable CTCSS so the
channel can be monitored prior to initiating dispatch from a
phone.
2. In key mode, the relay is on whenever the PTT is activated.
3. Remote Function provides a remotely controllable contact
closure/opening which can be used for any purpose.
Note: Option 9805 (Aux. Relay) is required for the above.
3.2. Remote Function Access Code
xxx = Any three digits
Protocol: #xxx relay ON
##xxx relay OFF
DEFAULT: 789
Sets the control code for the Aux. Relay Remote Function. Enter
any three digits. To turn on the relay press #xxx. To turn off
the relay press ##xxx. This functions only if you entered 3 on
line 3.1.
Note: The remote function can not be operated while in connect.