Note
The reset is effective immediately, restoring the previous settings is not possible!
Operating hours are not reset.
Not possible with customer service electronic devices.
2.3.24 Imbalance sensor
Adaptation of the imbalance and load calculation to existing sensors:
– speed sensor (Tachogenerator),
– imbalance sensor,
– load sensor.
x
Note
The programming option load sensor has to be activated for the load sensor to
display.
2.3.25 Water valves
Activation and fault monitoring of the water valves or water path control unit with 4
or 5 paths.
x
Note
Frontloaders, without chlorine bleach option, are equipped with a 4–position
water path control unit (M24).
Frontloaders with chlorine bleach option are equipped with a water path control
unit (M24) with an additional 5th position.
Refer to Appliance, Technical Data and Wiring Diagram.
2.3.26 Display
W 4800
Fascia panel with/without 7 segment display.
2.3.27 Appliance
The features required to control and monitor the housing lid, lid II and positioning
are deactivated.
Descriptive Technical Documentation
DTD no. 11-4800 070-7