2.3.8 Standby
When the standby function is activated, the display dims after 10 minutes, to
reduce energy consumption.
If the option not during a running program is selected, the standby function only
acts before and after a program cycle, not during a running program.
2.3.9 Water intake
Activation of hot water valve (Y12 / 2Y40).
Customization of the water intake control and the laundry process.
2.3.10 Max. water level
Adjustment of the laundry process for soft water areas.
Level III at rinse cycle.
2.3.11 Country version
Adjustment of the laundry process depending on the country of destination.
2.3.12 Max. spin speed
Adjustment of the final spin speed.
2.3.13 Load automatic
For detergent test facilities only.
Activate / deactivate intelligent water intake (IWE).
2.3.14 Imbalance values
Adjustment of the imbalance thresholds.
2.3.15 Central unit
Function data not available at this time.
2.3.16 Heater output
The heater output influences the wash cycle time/residual time indication.
2.3.17 Low water pressure
If the flow pressure is lower than 1 bar, the water intake monitor – water control
system (WCS) registers this as a fault, refer to 040 2.4 Water intake monitoring –
water control system (WCS).
Descriptive Technical Documentation
DTD no. 11-4800 070-5