x
Note
The program function Hygiene has to be activated for this intervention, refer to F
92 Bacterial control, 070 3.34.
2.3.33 Prewash at heavy soil
W 4800
With or without prewash when Heavy soil is selected.
2.3.34 Chlorine / Bleach agent intake
W 4840
To activate the chlorine / bleach agent intake.
Set the water path control for chlorine / bleach agent intake.
2.4 Service function
2.4.1 Component test
Activate electronic components.
Check the function visually, acoustically, and by observing the display.
2.4.2 Sensor test
Sensor signals are indicated.
Check the function visually, acoustically, and by observing the display.
So that all sensor functions can be checked, change test conditions manually,
moving from one test segment to another.
2.4.3 Operating hours meter
Time is counted from program start, not included are delay start and anti-crease.
The time is s tored in the electronic power program (ELP).
2.4.4 Operating
Operating functions are indicated.
Check the function visually, acoustically, and by observing the display.
So that all operating functions can be checked, change test conditions manually,
for example by pressing keypads.
Descriptive Technical Documentation
DTD no. 11-4800 070-9
22.12.2006, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.