Dil ID: 6
Dil Adı: turkish
Dil Kodu: tr2tayfun Miele Markası'nın Ürünleri
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



x
Note
The component test switches off automatically 30 minutes after the last
component is activated.
Service function
Component / Sensor
Program index /
Softwarestatus
With display: Software status, ID of power electronic (ELP), ID of control electronic
Without display: Program index, ID of power electronic (ELP), ID of control electronic
Check Fault
Memory
1)
and
delete
2)
Fault memory Fault code Remedy
No fault F 0 refer to F 0 No fault, 070 3.11
NTC short circuit water / heater F 1 refer to F 1 NTC short circuit water /
heater, 070 3.12
NTC open circuit water / heater F 2 refer to F 2 NTC open circuit water /
heater, 070 3.13
Water intake fault cold water F 10 refer to F 10 Water intake fault cold
water, 070 3.14
Water drain F 11 refer to F 11 Water drain, 070 3.15
Water intake fault hot water F 15 refer to F 15 Water intake fault hot water,
070 3.16
Oversudsing F 16 refer to F 16 Oversudsing, 070 3.17
Flow meter sluggish F 19 refer to F 19 Flow meter is sluggish (flow
meter (B3/4) / current volume meter), 070
3.18
Heater (Temperature in thermostop not
reached)
F 20 refer to F 20 Heater (R1), 070 3.19
Door does not lock F 34 refer to F 34 Door does not lock, 070
3.20
Door lock does not release F 35 refer to F 35 Door does not release, 070
3.21
Faulty EEPROM / Data faulty F 41 refer to F 41 Electronic fault (faulty
EEPROM / faulty data), 070 3.23
Appliance not programmed F 43 refer to F 43 Appliance model is not
programmed, 070 3.24
Connection I
2
C-Bus faulty F 44 refer to F 44 Electronic fault (defective
connection I
2
C-Bus), 070 3.25
Flash F 45 refer to F 45 Electronic fault (defective
flash RAM/ wrong data), 070 3.26
Display F 46 refer to F 46 Display, 070 3.27
Interface EW / ELP F 47 refer to F 47 Electronic fault (defective
interface EW/ELP), 070 3.28
Drive F 50 refer to F 50 Drive, 070 3.29
Pressure sensor F 51 refer to F 51 Pressure sensor, 070 3.30
Speed meter (tachogenerator) F 53 refer to F 53 Speed meter
(tachogenerator), 070 3.31
No spin F 56 refer to F 56 No spin action, 070 3.32
Water path control F 63 refer to F 63 Water path control fault, 070
3.33
Bacterial control F 92 F 92 Bacterial control, 070 3.34
Delete fault memory OK
Descriptive Technical Documentation
070-44 DTD no. 11-4800
This information should not be duplicated or passed on without Miele approval. All rights reserved. 22.12.2006, US_am