Service function
Option
Buzzer LED short Prewash LED long short
Software status
- Program index: ID of the power electronic (ELP), ID of the control
electronic (EW)
X Y
Check Fault
memory
1)
and
delete
2)
1 F 0, no fault, refer to F 0 No fault, 070 3.11 - -
F 1, NTC short circuit water / heater, refer to F 1 NTC short circuit
water / heater, 070 3.12
- 1
F 2, NTC open circuit water / heater, refer to F 2 NTC open circuit
water / heater, 070 3.13
- 2
F 10, Water intake fault (cold), refer to F 10 Water intake fault cold
water, 070 3.14
1 0
F 11, Water drain, refer to F 11 Water drain, 070 3.15 1 1
F 15, Water intake fault (hot), refer to F 15 Water intake fault hot water,
070 3.16
1 5
F 16, Oversudsing, refer to F 16 Oversudsing, 070 3.17 1 6
F 19, Flow meter sluggish, refer to F 19 Flow meter is sluggish (flow
meter (B3/4) / current volume meter), 070 3.18
1 9
F 20, Heater (Temperature in thermostop not reached), refer to F 20
Heater (R1), 070 3.19
2 -
F 34, Door does not lock, refer to F 34 Door does not lock, 070 3.20 3 4
F 35, Door lock does not release, refer to F 35 Door does not release,
070 3.21
3 5
F 41, Faulty EEPROM / Data faulty, refer to F 41 Electronic fault (faulty
EEPROM / faulty data), 070 3.23
4 1
F 43, Appliance not programmed, refer to F 43 Appliance model is not
programmed, 070 3.24
4 3
F 44, Connection I
2
C-Bus faulty, refer to F 44 Electronic fault
(defective connection I
2
C-Bus), 070 3.25
4 4
F 45, Flash, refer to F 45 Electronic fault (defective flash RAM/ wrong
data), 070 3.26
4 5
F 46, Display, refer to F 46 Display, 070 3.27 4 6
F 47, Interface EW / ELP, refer to F 47 Electronic fault (defective
interface EW/ELP), 070 3.28
4 7
F 50, Drive, refer to F 50 Drive, 070 3.29 5 -
F 51, Pressure sensor, refer to F 51 Pressure sensor, 070 3.30 5 1
F 53, Speed meter (tachogenerator), refer to F 53 Speed meter
(tachogenerator), 070 3.31
5 3
F 56, No spin, refer to F 56 No spin action, 070 3.32 5 6
F 63, Water path control, refer to F 63 Water path control fault, 070
3.33
6 3
F 92, Bacterial control, refer to F 92 Bacterial control, 070 3.34 9 2
Descriptive Technical Documentation
DTD no. 11-4800 070-47
22.12.2006, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.