WINDSHIELD WIPERS
Two speed electric pantograph wipers shall be installed. These wipers shall have minimum 24"
blades and have 28 1/2" wet arm electric pump washers. A 70 oz. Minimum windshield washer
reservoir shall be furnished.
STEERING WHEEL AND COLUMN
The steering column shall be a tilt / telescopic type with an integral high beam / turn signal control
switch. The column shall have self-canceling design for the turn signal switch. A 4-way warning
"Hazard" light switch shall be mounted on the column. For safety, a rubber boot shall be installed
to cover the steering shaft from the dash to the floor.
The steering wheel shall be a minimum of 18-inch diameter, covered with a padded absorbite
finish. A lever on the left side of the steering column shall control the telescopic feature of the
steering column.
FASTENERS
All cab exterior fasteners shall be stainless steel type fastened to the cab with nutserts.
BATTERY ACCESS
The rear cab steps shall have a removable kick panel, providing access to the batteries for routine
maintenance and inspection.
CAB CORROSION TREATMENT
The cab shall have a corrosion preventative material conforming to Mil Spec C-16173-C, Grade 1,
applied during and after construction. A 10-year warranty against perforation due to rust or
corrosion shall be furnished for the cab.
TRANSMISSION SELECTOR
The transmission shall be controlled by a push button type shift control. It shall be internally
illuminated for night operation.
TRANSMISSION OIL LEVEL SENSOR
The transmission shall be equipped with an oil level sensor. This sensor shall allow the operator to
obtain an indication of the fluid level from the shift selector.
RAISED ROOF EXTERIOR DIAMOND PLATE OVERLAY
The raised roof section of the cab shall be covered with NFPA slip resistant aluminum tread plate
to protect the cab roof from scratches.
EMI/RFI PROTECTION
The apparatus shall incorporate the latest designs in the electrical system with state of the art
components to insure that radiated and conducted electromagnetic interference (EMI) and radio
frequency interference (RFI) emissions are suppressed at the source.
The apparatus proposed shall have the ability to operate in the environment typically found in fire
ground operations with no adverse effects from EMI/RFI.