Dil ID: 7
Dil Adı: french
Dil Kodu: fr2tayfun Produits de la Marque CDA
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



Issue Date: 2010-03-02 Page 9 of 23 Report Reference # E336418-A29-UL
2010-10-22
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
TYPE A.
2.7.4 Number and location of protective devices ........... : One protective device in the
"LIVE" phase
Pass
2.7.5 Protection by several devices N/A
2.7.6 Warning to service personnel................................ : No protective device is
provided in the neutral
conductor.
N/A
2.8 Safety interlocks N/A
2.8.1 General principles No SAFETY INTERLOCKS
used.
N/A
2.8.2 Protection requirements N/A
2.8.3 Inadvertent reactivation N/A
2.8.4 Fail-safe operation N/A
2.8.5 Moving parts N/A
2.8.6 Overriding N/A
2.8.7 Switches and relays N/A
2.8.7.1 Contact gaps (mm)................................................ : N/A
2.8.7.2 Overload test N/A
2.8.7.3 Endurance test N/A
2.8.7.4 Electric strength test N/A
2.8.8 Mechanical actuators N/A
2.9 Electrical insulation Pass
2.9.1 Properties of insulating materials Natural rubber, materials
containing asbestos and
hygroscopic materials are not
used as insulation.
Pass
2.9.2 Humidity conditioning The humidity treatment was
conducted for 48 hrs.
Electric strength test was
conducted after the humidity
treatment.
Pass
Humidity (%) .......................................................... : 95 -
Temperature (°C)................................................... : 30 -
2.9.3 Grade of insulation Pass
2.10 Clearances, creepage distances and distances through insulation Pass
2.10.1 General Pollution degree 2 applicable.
FUNCTIONAL INSULATION
complied with Sub-clause
Pass