Issue Date: 2010-03-02 Page 6 of 23 Report Reference # E336418-A29-UL
2010-10-22
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
2.2.2
Voltages under normal conditions (V) ................... : All accessible voltages are
less than 42.4V peak or 60V
dc and are classified as SELV.
Pass
2.2.3 Voltages under fault conditions (V) ....................... : Under fault conditions voltages
never exceed 71V peak and
120V dc and do not exceed
42.4V peak or 60V dc for more
than 0.2 sec.
Pass
2.2.3.1 Separation by double insulation or reinforced
insulation (method 1)
SELV CIRCUITS are
separated from other circuits
by providing DOUBLE or
REINFORCED INSULATION
in the meaning of this
standard.
Pass
2.2.3.2 Separation by earthed screen (method 2) N/A
2.2.3.3 Protection by earthing of the SELV circuit (method
3)
N/A
2.2.4 Connection of SELV circuits to other circuits ........ : SELV CIRCUITS are only
connected to other SELV
CIRCUITS and/or LIMITED
CURRENT CIRCUITS.
Pass
2.3 TNV circuits N/A
2.3.1 Limits No TNV presents. N/A
Type of TNV circuits .............................................. : -
2.3.2 Separation from other circuits and from accessible
parts
N/A
Insulation employed............................................... : -
2.3.3 Separation from hazardous voltages N/A
Insulation employed............................................... : -
2.3.4 Connection of TNV circuits to other circuits N/A
Insulation employed............................................... : -
2.3.5 Test for operating voltages generated externally N/A
2.4 Limited current circuits Pass
2.4.1 General requirements The current measured
between the user accessible
part of a limited current circuit
by IEC leakage current meter.
Conducted on bridging
capacitor CY1.
Pass
2.4.2 Limit values 0.7 mA peak. Pass
Frequency (Hz)...................................................... : 60 Hz -