Issue Date: 2010-03-02 Page 7 of 23 Report Reference # E336418-A29-UL
2010-10-22
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
Measured current (mA).......................................... : 0.165 MIU maximum.
-
Measured voltage (V) ............................................ : 354 V peak maximum. -
Measured capacitance (mF).................................. : CY1: 2200 pF. -
2.4.3 Connection of limited current circuits to other
circuits
The LIMITED CURRENT
CIRCUIT connected to other
circuits complies with the
requirements of Sub-clause
2.4.1.
N/A
2.5 Limited power sources Pass
Inherently limited output Pass
Impedance limited output N/A
Overcurrent protective device limited output N/A
Regulating network limited output under normal
operating and single fault condition
Pass
Regulating network limited output under normal
operating conditions and overcurrent protective
device limited output under single fault condition
N/A
Output voltage (V), output current (A), apparent
power (VA):............................................................ :
For Model GT-41069P9012-
T3YZ:
Uoc = 12.2 V, Isc = 8.0 A, VA
= 96 VA.
For model GT-41069P9024-
3.75-T3YZ:
Uoc = 24.2 V, Isc = 4.0 A, VA
= 96 VA..
-
Current rating of overcurrent protective device (A): -
2.6 Provisions for earthing and bonding Pass
2.6.1 Protective earthing N/A
2.6.2 Functional earthing Functional earthing separated
from Hazardous voltage by
reinforced insulation.
Functional Earthing connected
to protective bonding.
Insulation on functional
earthing conductor is not
green-yellow.
Pass
2.6.3 Protective earthing and protective bonding
conductors
Pass
2.6.3.1 General Pass
2.6.3.2 Size of protective earthing conductors Power supply cord earthing
conductor complies with Table
3B (Optional provided).
Pass