Issue Date: 2010-03-02 Page 5 of 23 Report Reference # E336418-A29-UL
2010-10-22
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
2
PROTECTION FROM HAZARDS
Pass
2.1 Protection from electric shock and energy hazards Pass
2.1.1 Protection in operator access areas Pass
2.1.1.1 Access to energized parts The operator has access to
bare parts of SELV CIRCUITS.
Pass
Test by inspection.................................................. : The OPERATOR cannot
contact with any parts with
only BASIC INSULATION to
ELV CIRCUITS or
HAZARDOUS VOLTAGES.
Pass
Test with test finger ............................................... : The test finger was unable to
contact bare hazardous parts,
basic insulation, or ELV
circuits.
Pass
Test with test pin.................................................... : The test pin was unable to
contact bare hazardous parts.
Pass
Test with test probe ............................................... : No TNV presents. N/A
2.1.1.2 Battery compartments ........................................... : N/A
2.1.1.3 Access to ELV wiring N/A
Working voltage (V); minimum distance (mm)
through insulation .................................................. :
-
2.1.1.4 Access to hazardous voltage circuit wiring N/A
2.1.1.5 Energy hazards ..................................................... : The output of the power supply
is not an energy hazard.
Pass
2.1.1.6 Manual controls N/A
2.1.1.7 Discharge of capacitors in equipment The voltage at the external
point of disconecttion did
decay to less than 37 percent
of its original value in 1.0
second.
Pass
Time-constant (s); measured voltage (V).............. : CX1 = 0.47 uF.
Measurements taken from line-
to-Neutral.
Vo (V pk) = 376 max.
37% Vo (V pk) = 139.1 max.
Vtc (V pk) = 98 max.
-
2.1.2 Protection in service access areas N/A
2.1.3 Protection in restricted access locations N/A
2.2 SELV circuits Pass
2.2.1 General requirements SELV levels are maintained
after single fault condition.
Pass