DELTA2 Owner's Manual 13 RSF Woodburning Fireplaces
CEILING CLEARANCE
Ceiling clearance is the distance from the base of the fireplace to the ceiling.
Under no circumstances should the distance between the ceiling firestop and the base fireplace be less than the
dimension specified in Table 1 (C).
OUTSIDE AIR DUCT
After the fireplace is correctly positioned, connect the outside air inlet to the outside (see Figure 10).
Use an insulated aluminium flexible duct rated
at over 200° F. The duct should not exceed
12' vertical rise above the base of the unit.
The air inlet should never be less than 5'
below the top of the chimney flue and
must never terminate in attic spaces.
A 4" diameter duct can be used if the total
duct run is less than 25'. For longer runs, use
5" diameter duct. Both 4" and 5" connecting
sleeves are provided with the fireplace.
1. Find a convenient location for the
combustion air duct and outside air inlet.
The outside air inlet can be above or
below floor level.
2. Make a 4 ¼" (5 ¼" if using a 5" diameter
duct) hole in the outside wall of the house.
Push the outside air inlet in from the
outside. Seal the joint between the air
inlet and the outside wall with an
appropriate sealant.
3. Place the insulated flexible duct over the round sleeve on the outside air inlet. At both ends, carefully pull
back the insulation and plastic cover, exposing the flexible duct. Then at each end, attach the duct with metal
screws to the inlet and tube. Carefully push the insulation and cover back over the duct. Tape the plastic
cover in place with 2" aluminium duct tape.
CAUTION: WHEN RUNNING THE DUCT AROUND CORNERS, BE SURE TO PREVENT CRIMPING THE
DUCT THAT WOULD RESTRICT THE COMBUSTION AIRFLOW.
CHIMNEY
This fireplace is certified for use with 8" ICC Model EXCEL chimney only. Please refer to Table 1 (D-E) for the
minimum and maximum chimney height permitted with the DELTA2 fireplace.
We recommend that the minimum height be increased by approximately 1' for every 2000' elevation above sea
level. Every 30° or 45° elbow also increases the minimum height by 1' For example, if you are living 6000' above
sea level, your chimney should terminate at least 15' from the top of the fireplace (12' + 3' for the 6000'). See
Table 2 for more precise recommended flue heights.
Above Floor
Example
Below Floor
Example
R
S
F
F
i
r
e
p
l
a
c
e
R
S
F
F
i
r
e
p
l
a
c
e
R
S
F
F
i
r
e
p
l
a
c
e
2" Aluminium
Duct Tape
Insulated Flexible Air Duct
Outside Wall
Outside Air
Inlet
Figure 10 Outside Air Connection and Installation
Exam
p
le