Printer Calibration - Error Messages Description and Corrective Action
Off line: Error: PRE-MAG
Press RESET to Continue
This message indicates an error
occurred, in the ZONE 1 Pre-Magnetic
Sensor (PRE-MAG), during the sensor
calibration procedure.
This error can occur when:
Media dust or debris obstructs the
Pre-Magnetic Sensor.
The Pre-Magnetic Sensor cable fails
or is not connected properly.
The Pre-Magnetic Sensor fails.
A component fails on the Main
Controller PCB.
To correct this error:
1. Perform the cleaning procedures and
vacuum out all media dust and debris.
2. If this error continues, power the unit
off and check internal cable
connections