In the Filter Action configuration section,
• Event Filter Action is a mandatory field and checked by default, which
enable PEF Alert action (read-only).
• Select any one of the Power action either Power down, Power reset or
Power cycle from the drop down list
• Choose any one of the configured alert policy number from the drop
down list.
NOTE: Alert Policy has to be configured - under Configuration->PEF->Alert Policy.
5
In the Sensor configuration section,
• Select the type of sensor that will trigger the event filter action.
• In the sensor name field, choose the particular sensor from the sensor
list.
• Choose event option to be either All Events or Sensor Specific Events.
6
Click
Modify
to accept the modification and return to Event filter list.
7
Click
Reset
to reset the modification done.
8
Click
Cancel
to cancel the modification and return to Event filter list.
9
In the Event filter list, click
Modify
to modify the existing filter.
10
In the Event filter list, click
Delete
to delete the existing filter.