Event Filter Tab
A PEF implementation is recommended to provide at least 16 entries in the
event filter table. A subset of these entries should be pre-configured for
common system failure events, such as over-temperature, power system
failure, fan failure events, etc. Remaining entries can be made available for
’OEM’ or System Management Software configured events. Note that
individual entries can be tagged as being reserved for system use - so this ratio
of pre-configured entries to run-time configurable entries can be reallocated if
necessary.
The fields of PEF Management - Event Filter Tab are explained below.
This page contains the list of configured PEF’s.
Table 1-21. PEF Management - Event Filter
Item Description
PEF ID This field displays the ID for the newly configured
PEF entry (read-only).
Filter configuration Check box to enable the PEF settings.
Event Filter Action Check box to enable PEF Alert action. This is a
mandatory field.
Sensor Name To choose the particular sensor from the sensor list.
Add To add the new event filter entry and return to Event
filter list.
Modify To modify the existing entries.
Cancel To cancel the modification and return to Event filter
list.