Issue Date: 2010-03-02 Page 14 of 23 Report Reference # E336418-A29-UL
2010-10-22
IEC 60950-1
Clause Requirement + Test Result - Remark Verdict
3.3.4
Conductor sizes to be connected N/A
Rated current (A), cord/cable type, cross-sectional
area (mm²)............................................................. :
-
3.3.5 Wiring terminal sizes N/A
Rated current (A), type and nominal thread
diameter (mm) ....................................................... :
-
3.3.6 Wiring terminals design N/A
3.3.7 Grouping of wiring terminals N/A
3.3.8 Stranded wire N/A
3.4 Disconnection from the mains supply Pass
3.4.1 General requirement Pass
3.4.2 Disconnect devices The Appliance Inlet is used as
the disconnect device.
Pass
3.4.3 Permanently connected equipment N/A
3.4.4 Parts which remain energized N/A
3.4.5 Switches in flexible cords No isolating switches fitted in
flexible cords.
N/A
3.4.6 Single-phase equipment and d.c. equipment Disconnect device disconnects
all poles simultaneously.
Pass
3.4.7 Three-phase equipment N/A
3.4.8 Switches as disconnect devices N/A
3.4.9 Plugs as disconnect devices N/A
3.4.10 Interconnected equipment N/A
3.4.11 Multiple power sources N/A
3.5 Interconnection of equipment Pass
3.5.1 General requirements Interconnection circuit did
continued conformance to the
requirements of SELV
CIRCUITS.
Pass
3.5.2 Types of interconnection circuits ........................... : Interconnection circuits are
SELV CIRCUITS/LIMITED
CURRENT CIRCUITS.
Pass
3.5.3 ELV circuits as interconnection circuits N/A