UPDATED: 6/2014 Instruction Manual IM-268-11 2014© Bally Refrigerated Boxes, Inc. 8
5. Making electrical connections to Entrance Doors and Installing Vapor-proof Lights
A. Electrical connections to the Walk-In doors are made at the top interior of each door panel. Remove the socket plate to expose
the wire connections in the junction box.
B. Remove the short wire “pigtails” and connect the service at the wire nuts, through the hole provided in the junction box. Refer to
serial tag for proper electrical characteristics. Insure that the electrical service is properly grounded. See Figure 18. Remount the
vapor-proof light assembly after all connections have been made.
Do not turn on power to door section until after the
refrigeration system has been started.