3.15 F 11 Water drain
Symptom
The message in the operating mode: Water drain fault.
The LED “check water drain” flashes.
The program is stopped and the drain pump is switched on for 120 seconds.
Water drain control, refer to 050 2.1 Water drain monitoring.
Cause
Insuf ficient drainage.
Remedy
A Check the foreign body trap.
A Drain the drain hose.
A Check the non return device.
A Check the air circulation to and from the drain pump.
A Check the function of the drain pump.
3.16 F 15 Water intake fault hot water
Symptom
The message in the operating mode: Hot water intake fault.
The LED “check water intake” lights up steadily.
The fault is not indicated in the operating mode.
The program is continued with cold water.
Water intake control, refer to 040 2.4 Water intake monitoring – water control
system (WCS).
Cause
Hot water faucet is closed.
Remedy
A Open the hot water faucet.
Cause
Water intake filters are gunked up.
Descriptive Technical Documentation