Observe the dosage recommendation.
A Observe the dosage recommendations of the detergent manufacturer, and
keep in mind the water hardness and degree of soiling.
Cause
Air circulation hose is clogged, causing an increase in pressure during water
intake.
Remedy
A Clean the air circulation hose.
Cause
Malfunction in the cycle.
Remedy
A Check the drain and the drain pump.
3.18 F 19 Flow meter is sluggish (flow meter (B3/4) / current volume
meter)
Symptom
The fault is not indicated in the operating mode.
Or water intake fault.
Fault detection: The fault is detected if during water intake an increase in the
water level is registered, but the control does not have a signal from the flow
through meter (B3/4) / current volume meter.
Flow through meter (B3/4), refer to 040 2.6 Flow meter (B3/4).
Water intake control, refer to 040 2.4 Water intake monitoring – water control
system (WCS).
Cause
Water intake fault.
Remedy
A Correct the water intake fault. Refer to F 10 Water intake fault cold water, 070
3.14.
Cause
No, or too few, impulses from the reed float of the flow through meter (B3/4).
Descriptive Technical Documentation
070-22 DTD no. 11-4800