3.10 Display indicates: Technical fault
Symptom
In the operating mode, the display shows: Technical fault.
Fault code indication.
The program is stopped, the water intake valve is closed, and the drain pump is
switched on for 120 seconds.
Cause
The power electronic (ELP) or the control electronic (EW) has registered a
technical fault.
The power electronic (ELP) stops the program.
Remedy
A Search the fault memory, refer to Service mode Overview, 070 4.5, Service
Mode Overview, 070 4.6.
A Refer to the M. No. and check if the correct control electronic (EW) and power
electronic (ELP) are installed.
A Check the electronic connection between the power electronic (ELP) and the
control electronic (EW).
3.11 F 0 No fault
Cause
No fault is saved to the power electronic (ELP).
Remedy
A No action needed.