Symptom Itemstocheck Resolution
Tub turning
during washing
Open the door and check if the tub is rotating.
•
Remove any alien substances
between the lever clutch and the
link valve drain.
•
Disassemble the rotor and check
the clutch and any damage in the
coupling.
•
Replace the spring lift.
Water supply
is not turned off
Wateriscontinuouslylledupevenwhenthe
machine is turned off.
•
Replace the water supply valve.
After reaching
theHIGHlevel,
water supply
continues.
•
Check whether the
water level hose is
folded.
•
Check whether the
water level hose is
lledwithwater.
•
Operation is normal
when the water level
is set to “Medium”
•
Unfoldthewaterlevelhoseandx
the condition.
•
Air leaks from water level hose.
•
Replace the water level sensor or
hose.
•
Replace the water level sensor.
Water draining
does not work
Check whether the drain hose is placed on the
oor
•
Lower the drain hose.
Check the
operation of
the drain
synchronous
motor
•
Check the voltage
between the
terminals of the drain
synchronous motor
•Replacethedrainsynchronous
motor if the terminal voltage is
abnormal.
•Ifnot,checktheharnessconnection
•Ifeverythingisok,thenreplacethe
PCB.
Check the connection between the link valve
drain and the sync motor.
•
Connect the sync motor to the link.
➡
➡