Dil ID: 14
Dil Adı: sloavakia
Dil Kodu: sk9tayfun Produkty značky Shure
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



Shure UC2 Hand-Held UHF Transmitter
Alignment1925C1044 (TK)
Option 2 Using a Modified SC4 IF Receiver
Deviation tests can also be performed using a modified SC4 IF
receiver. For instructions on modifying an SC4 receiver, consult the
Shure Service Equipment manual.
Reference Voltage
1. See Figure 12 for equipment test set-up and equipment settings.
2. Connect the rf signal generator output to the input port (L) of a
Zad-1 mixer
3. Connect the output port I (intermediate frequency) of the Zad1
mixer to antenna input B of the SC4 IF receiver.
4. Turn the SC4 IF receiver ON and set the tone key switch on the
front panel of the SC4 IF receiver to OFF.
5. Connect the audio voltmeter to the receivers unbalanced output.
6. Measure the output voltage.
Record this voltage. This is the deviation reference voltage.
Use the same Zad-1 mixer connections for the next adjustment test.
RF SIGNAL GENERATOR
AUDIO ANALYZER
DC BLOCK
NOTE: DC VOLTAGES ARE
PRESENT AT MOST RF TEST
POINTS. USE A DC BLOCK
ON THE RF SIGNAL GENERATOR
TO PROTECT TEST EQUIPMENT.
R
I
L
ZAD1 MIXER
MODIFIED SC4 IF RECEIVER
ANTENNA INPUT B
AUDIO OUT
TONE KEY SWITCH: OFF
SC4 IF Receiver Audio Analyzer Rf Signal Generator
Output: Unbalanced Measurement: AC level INT: FM
Gain: Maximum Filters: INT: 1 kHz
Squelch: Mid Low-Pass (30 kHz): ON Output amplitude: + 7 dBm
Tone Key switch: OFF High-Pass (400 Hz): ON Frequency: 10.7 MHz
Operating freq: See Table 2 Deviation: See Table 2
Figure 11. Deviation Reference Voltage Test Set-Up,
Using a Modified SC4 IF Receiver