NLLW – návod k obsluze a instalaci
Paramete
r
Value Note Default
46 c
Time waiting for confirmation cx5 [sec]
5
c – 5 ÷ 50 sec (0 = 50 sec) is time which after number dialing the LLW
waiting for call confirmation. It is calculate that value c ( number dial from
phone during programming) is x 5 .
List of corresponding parameters: 1 21 22 45
Paramete
r
Value Note Default
47 e
Time without ringing tone – call detection
5
e – 1 ÷ 10 sec (0 = 10 sec) is time for which is not detected ringing tone after
dialing of number. If is set at number dial without confirmation then is set that
call started.
List of corresponding parameters: 1 21 22
Paramete
r
Value Note Default
48 rr
Code rr for switching relay from phone
55
rr - code for switching relay from phone (2 digits)
List of corresponding parameters: 49
Paramete
r
Value Note Default
49 ss
Time of relay switching ss [sec]
05
ss - time [sec] of relay closing after dialing of code from phone (2 digits)
List of corresponding parameters: 48