NLLW – návod k obsluze a instalaci
35 b
Button blocking - input BLOCK
0
b – 0 emergency call is blocking by voltage connection 5-24V
– 1 emergency call is blocking by voltage disconnection 5-24V
List of corresponding parameters: 1 53
Paramete
r
Value Note Default
36 c
Time of service call repeating
5
c – 0 ÷ 9 – unsuccessful service call is repeated after time 0 ÷ 9 minutes.
This time is adjustable to repeated service call from more LLW doesn’t
come in same time.
List of corresponding parameters: 31 56
Paramete
r
Value Note Default
37 d
Number of emergency call sequence repetation
1
d – 1 ÷ 5 times is repeated dial of emergency numbers (button pressing).
Emergency numbers are dialed from first position until empty or 6th
position. This is 1 sequence. It might be repeated max 5 times.
List of corresponding parameters: 1
Paramete
r
Value Note Default
38 e
Time of failure duration before failure calling is
activated
1
e – 0 ÷ 9 is time [sec] of permanent failure duration on input INP1 to be
activated failure calling
List of corresponding parameters: 22 33 34