NLLW – návod k obsluze a instalaci
4.2 Operation
Paramete
r
Value Note Default
31 a
Service calling is in status ON / OFF a
0
a – 0 service calling OFF
– 1 service calling ON after time set in parameter 56
– 2 service calling ON after time set in parameter 56 and moreover is
activated during first telephone line connection
service calling is activated after time set in parameter 56 and is repeated after
time period set in parameter 36
Paramete
r
Value Note Default
32 h
For service calling are used also emergency
numbers
0
h – 0 emergency numbers are not used. It is calling only number program in
parameter 21
– 1 emergency numbers are used. It is calling numbers programmed in
parameter 21 and 1
List of corresponding parameters: 1 21 31 56 36
Paramete
r
Value Note Default
33 i
For failure calling are used also emergency
numbers
0
i – 0 emergency numbers are not used. It is calling only number programm
in parameter 22
– 1 emergency numbers are used. It is calling numbers programmed in
parameter 22 and 1
List of corresponding parameters: 1 22 34 38
Paramete
r
Value Note Default
34 z
Activation of failure calling on input INP1
0
z – 0 failure calling is activated by voltage connection 5-24V
– 1 failure calling is activated by voltage disconnection 5-24V
List of corresponding parameters: 1 21 33 38
Paramete
r
Value Note Default