POLY BIN
Three white .5 thick poly bins with lifting slots shall be provided. The bin(s) shall measure 21.5"
wide x 20.0" long x 13.0" high.
APPARATUS BODY ELECTRICAL SYSTEM
All body electrical shall conform to NFPA 1901 latest edition standards. The apparatus shall be
equipped with a heavy-duty 12-volt negative ground system.
The apparatus shall be equipped with a Class1 Es-Key Management System for complete control of
the electrical system devices.
The left rear compartment shall house the relay based Power Distribution Module (PDM). The
PDM shall be mounted on a removable panel in the left rear compartment with sufficient harness
length to allow a technician the ability to remove the PDM and place it on a compartment shelf for
diagnostics and service. All wiring shall be color-coded and function coded. All circuits shall be
divided and balanced for proper load distribution. Where possible, wiring shall be routed in looms
as a single harness. Heat resistant convoluted loom shall be used. Only solderless, insulated crimp
automotive electrical connectors shall be used.
GENERATOR
An Onan model 35.0YD-CR/621, 35 KW PTO generator system shall be supplied and installed on
the apparatus. The generator system shall be capable of producing 35 KW, single phase, 120/240-
volts at 60 hertz regardless of engine RPM. The generator shall be equipped with an automatic
voltage regulator to maintain nominal output voltage (120/240-volts AC) under varying generator
loads.
The generator display module shall display generator output voltage, frequency and current. The
display module shall be located in the L1 compartment adjacent to the apparatus load center. The
load center shall be connected to the generator system.
A PTO unit shall be provided and installed. A switch to control the operation of the PTO shall be
installed in the drivers switch panel.
120/240-VOLT AC NFPA LOAD TEST
Electrical System Testing.
The wiring and associated equipment shall be tested by the apparatus manufacturer
Operational Test
The apparatus manufacturer shall perform operational test and shall certify that the power source
and any devices that are attached to the line voltage electrical systems are properly connected and
in working order.
The results of the tests shall be supplied to the Town at the time of delivery.
LOAD CENTER PANEL
A Square D Homeline circuit breaker panel shall be provided in the apparatus body. All breakers
shall be properly labeled. The generator shall be hard wired to the circuit breaker panel. The circuit
breaker panel shall be mounted so as to not interfere with shelves or trays, if specified. The load
center panel cover shall be accessible with hand tools. The load center panel mounting location