13
GB
Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the
type plate. The position of the type plate is shown in the section
entitled Description of the appliance.
Thesocketmustbeproperlyearthedandprotectedbyafuse.
The tripping current of the fuse must be between 10 A and 16 A.
Thesocketmustnotbesituatedbehindtheappli-
ance and must be easily accessible.
Donotconnecttheapplianceusinganexten-
sioncableorextensionsocket.
Donotusestand-aloneinverters(conversion
of direct current to alternating/three-phase
current)orenergy-savingplugs.Riskofdam-
agetotheelectroniccontrolsystem!
GGPv 14.. equipment
Intermediate shelves
Place the supplied intermediate shelves onto the shelf rails.
Note
The maximum load per intermediate shelf is 20 kg.
Fit the supplied shelf rails to the right
and left of the vertical bar.
Suspend the rails at the desired
height, by inserting into the rear
clip-instriprstandthenclippingin
at the front.
Safety lock
Thelockisequippedwithasafety
mechanism.
Locking the appliance
• Insert the key as shown by ar-
row 1.
• Turnthekey180°(2).
Tounlocktheappliance,thesame
procedure must be repeated in the
same order.
Insertthegridshelves.
Equipment
GGPv
65..
GGPv
14..
The BGPv series is equipped
with L-shaped support rails to
accommodatebakingtrays.
Depending on the height of
the goods to be stored, you
can adjust the position of the
support rails in intervals of
27,5 mm.
First slide bars into the rear
clip-in upright at the desired
height and then hang in posi-
tion at the front.
BGPv equipment