Connect Systems Inc. - Model 9800 Page 40
Select
Tone #
1
EIA
2
ZVEI1
3
CCIR/
EEA
4
CCIT
5
EURO
6
ZVEI2
0
1
2
3
4
5
6
7
8
9
R
600
741
882
1023
1164
1305
1446
1587
1728
1869
459
2400
1060
1160
1270
1400
1530
1670
1830
2000
2200
2600
1981
1124
1197
1275
1358
1446
1540
1640
1747
1860
2110
400
697
770
852
941
1209
1336
1477
1633
1800
2200
980
903
833
767
707
652
601
554
511
471
1063
2400
1060
1160
1270
1400
1530
1670
1830
2000
2200
970
TABLE 4
5/6 TONE SEQUENTIAL CODES
(line 4.3. = 3)
Select one of the groups from the table above and enter on (5.2.)
The first two tones of a 1000 call five tone sequence are selected
from the appropriate group and entered on (4.8.) and (4.9.) These two
tones will automatically be sent with each page.
The third, fourth and fifth tones of the five tone sequence become the
selective call code and are selected under the chosen operating group.
Example: A pager sequence of 1023, 1305, 1587, 741 and 1446 HZ is
required. Enter 1 (EIA) on line 5.1. Enter 3 on line 4.8. Enter 5 on
line 4.9. The three digit selective call code is then = 716.
To increase the probability of successful signalling, the five tones
can be automatically repeated up to nine times (5.0.).
A sixth preamble tone can be enabled (4.6.) and selected (4.7.) if
required.
The desired tone duration can also be selected (5.1.)
NOTES: 1. 5/6 tone signalling is an option and will not function
unless signaling option is factory installed.
2. See 'Incoming Calls' in the Operation section to
determine the proper use of the selective call codes
determined from this table.