Test program
The machine control unit incorporates a built-in test program which can be used for faultfinding.
The machine can be provided with various silicon chips for different markets, which is why we have
numbered the buttons as shown in the figure below:
S1
S2
S4
S5
S3
S6
Hold down
Start
Stop
and at the same time press S5 5 times in 15 seconds to start level 1 of the test program
(see below).
Press S6 once to reach level 2.
Press S6 again to return to level 1.
Start
Stop
ends the test program.
Select level 1
S1 Inlet valve 1 (pre-wash compartment)
S2 Inlet valve 2 (main wash compartment)
S3 Inlet valve 3 (hot water)
S4 Inlet valve 4 (washing powder compartment)
S5 Door pull magnet
Select level 2
S1 Heating relay (clicking sound from relay on control unit).
S2 Drain pump
S3 Motor, normal running
S4 Motor, economy running
S5 Long spin