Dil ID: 1
Dil Adı: english
Dil Kodu: en1 Winterhalter Brand's Products
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



1616161616
16 89007312
10 Faults
10.1 Faults where it is not necessary to call Winterhalter Services
You can rectify minor faults yourself following the steps described in the table below. If you are unable to
rectify the fault, contact Winterhalter service.
DANGER! Danger of death due to live components!
Do not open any panels or expose any parts of the machine if tools are necessary to do so.
Risk of electric shock.
Work on the electrical equipment is only to be carried out by specialist personnel. First
disconnect the washer from the mains.
Do not switch the washer on again until the cause of the fault has been identified.
Turn off the main switch on the machine. The dishwasher is then isolated from the power
supply.
Display Cause Remedy
The washer
cannot be
switched on
The mains disconnecting device (mains
switch) provided by the customer is not
switched on.
Customer’s fuses blown
Switch on the mains disconnecting device
(mains switch) provided by the customer.
Replace the customer’s fuses
Wash
programme does
not start
Door not fully closed
Machine not ready for operation
Close the door.
Switch on the mains disconnecting device
(mains switch) provided by the customer,
open the water stop valve and switch on the
machine
Dishes are not
clean
Detergent or rinse aid storage tank is
empty
Filter cartridge and/or flat filter is dirty
Wash jets in the wash arms blocked
Functional fault in the water treatment
Top up the storage tank
Clean the filter cartridge and flat filter
Clean wash jets. The end pieces of the wash
fields can be removed.
Call Winterhalter service engineer
Limescale build-
up, even though
the machine has
an integral water
softener
No regenerating salt added
Add regenerating salt. If this does not bring
about an improvement, call Winterhalter
service
Out of regeneration salt
Top up with regeneration salt and perform a
washing program immediately to flush out
any salt residues. Otherwise there is a risk
of rust forming in the filling area. The symbol
goes out at the latest after the third cycle.
Display shows:
External water treatment system needs
regenerating
Regenerate external water treatment system