Dil ID: 1
Dil Adı: english
Dil Kodu: en4 Unitor Brand's Products
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



205205205205205
SPN CID SID PID PPID FMI
John Deere
Volvo
Perkins
Description Comment
656 6 6 656 Cylinder #6 injector status
0
Injector outside the specifications
Recalibration of the injectors
required
1 Injector outside the specifications
Recalibration of the injectors
required
2 Short circuit high side to B+
3
Short circuit high side to low side or low
side to B+
4 Short circuit high or low side to ground
5 Cylinder #6 circuit open
6 Cylinder #6 circuit shorted
7
Cylinder #6 balancing error/mechanical
failure
11
Cylinder #6 unknown error/mechanical
failure
676 39 Glow plug relay status
3
Glow plug relay voltage high
5 Glow plug relay voltage low
677 39 3 Start relay status
3
Start relay control short circuit to high
4 Start relay control short circuit low
5 Start relay control open circuit
678 41 8 Volt power supply
3
ACM 8 Volt DC supply open/short to B+
4
ACM 8 Volt DC supply open/short to
ground
679 42
Regulation sensor of the injection
pressure control
723 342 Secondary speed sensor
2
Secondary engine speed sensor data
intermittent
11
Secondary engine speed sensor loss of
signal
12 Loss of signal/sensor failure
729 70
Inlet air heater signal/Preheat
detection
3
Inlet air heater signal high
5 Inlet air heater signal low
810 Vehicle speed
2
Calculated vehicle speed input noise
Not possible with Genset
application
861 861 Diagnostic output status
3
Diagnostic output open/short to B+
4 Diagnostic output short to ground
898 CAN throttle status
9
Speed value invalid or missing
970 6
A
uxiliary engine shutdown switch
status EMS
2
Auxiliary engine shutdown switch signal
invalid
Not used
31 Auxiliary engine shutdown switch active
971 External engine de rate switch status
31
External engine de rate switch active Not used
203/209