Dil ID: 1
Dil Adı: english
Dil Kodu: en4 Unitor Brand's Products
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



203203203203203
SPN CID SID PID PPID FMI
John Deere
Volvo
Perkins
Description Comment
639 247 231 Communication status
2 Bus Off error
9 Passive bus error
11 Data registers read back failure
12 Loss of message error
13 Bus CAN error
640 Engine shutdown vehicle status
11
Engine shutdown vehicle request invalid
31 Engine shutdown vehicle request
641
Status of the Turbo with variable
geometry
4
Supply voltage of the Turbo actuator low
12
Error in communication between the ECU
and the TGV actuator
13 Error in position of the TGV
16
Temperature of the actuator moderately
high.
647 Fan supply
3
Short circuit to earth
5 Open circuit
651 1 1 651 Cylinder #1 injector status
0
Injector outside specifications
Recalibration of the injectors
required
1 Injector outside specifications
Recalibration of the injectors
required
2 Short circuit high side to B+
3
Short circuit high side to low side or low
side to B+
4 Short circuit high or low side to ground
5 Cylinder #1 circuit open
6 Cylinder #1 circuit shorted
7
Cylinder #1 balancing error/mechanical
failure
11
Cylinder #1 unknown error/mechanical
failure
652 2 2 652 Cylinder #2 injector status
0
Injector outside the specifications
Recalibration of the injectors
required
1 Injector outside the specifications
Recalibration of the injectors
required
2 Short circuit high side to B+
3
Short circuit high side to low side or low
side to B+
4 Short circuit high or low side to ground
5 Cylinder #2 circuit open
6 Cylinder #2 circuit shorted
7
Cylinder #2 balancing error/mechanical
failure
11
Cylinder #2 unknown error/mechanical
failure
201/209