Dil ID: 6
Dil Adı: turkish
Dil Kodu: tr7 Xerox Markasının Ürünleri
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



8825/8830 Controller Setup Manual for Firmware 6.0 69
Configuring the Printer Setup Defaults (continued)
Setting The Maximum Plot Length
Option
The Purpose of the Maximum Plot Length Option
This option sets the maximum plot length which can be printed, in inches.
Range: 48 inches (4 feet) (122 cm) to 960 inches (80 feet) (2438 cm)
Default: = 960 inches (2438 cm)
The value displayed on the Control Panel is expressed in centimeters. There
are 2.54 cm in one inch.
When the maximum plot length is set to a specified length, plots that are
longer then this value will be terminated. This value is data format
independent. If your plots are being cut at a length less than you expect,
check this value.
PATH TO TIME OUT OPTION
Display <IDLE>, press [ON-LINE], display <PAUSED>, press [ENTER],
display <UTILITIES>, press [NEXT] until <SETUP PRINTER> is displayed,
press [ENTER], display <BANNER PAGE>, press [NEXT] until <MAXIMUM
PLOT LENGTH> is displayed.
SELECTING TIME OUT OPTION
Press the ENTER key to change plot length value. Input value (122 - 2438)
CM on the Keypad. With the desired value displayed, press the ENTER key.
EXITING TIME OUT OPTION
Press EXIT to set up additional functions. Press the ON-LINE key to go back
to ON-LINE mode.