412
3300 ICP Technician’s Handbook
Figure 173: SX-2000 MicroLIGHT under 3300 control
Collecting System Logs Manually
Collecting System Logs - Release 5.1 System
To collect the logs on a Release 5.1 system:
1. Log into the System Administration Tool (see page 71).
2. Select System Diagnostics and then click Export.
3. Click Export and then click Continue.
4. After the File Download dialog box appears, click Save.
5. Navigate to a folder or network drive on your PC. Ensure that the file
extension is set to (.tar).
6. Click Save and then click Close.
To collect the logs through PC to controller network connectivity:
1. At the DOS prompt, type cd c:\3300log (example folder name)
Type ftp <ip address of the controller>
Enter the ESM username and password when prompted.
You should see the ftp prompt when you successfully log in.
Type binary
Type hash
Type prompt