3.23 F 41 Electronic fault (faulty EEPROM / faulty data)
Symptom
The program runs at default values.
In the operating mode the display indicates: Technical fault.
The program is stopped, the water intake valve is closed, and the drain pump is
switched on for 120 seconds.
The fault indication will be deleted when the appliance is disconnected from
power.
Cause
Internal defect of power electronic (ELP).
Remedy
A If no malfunction exists, no action is required.
A Replace the power electronic (ELP).
3.24 F 43 Appliance model is not programmed
Symptom
In the operating mode the display indicates: Technical fault.
It's not possible to start a program.
Cause
Control electronic (EW) and power electronic (ELP) are not compatible.
Remedy
A Refer to the M. No. and check if the correct control electronic (EW) and the
correct power electronic (ELP) are installed.
Descriptive Technical Documentation
070-26 DTD no. 11-4800
This information should not be duplicated or passed on without Miele approval. All rights reserved. 22.12.2006, US_am