3.25 F 44 Electronic fault (defective connection I
2
C-Bus)
Symptom
In the operating mode the display indicates: Technical fault.
The program is stopped, the water intake valve is closed, and the drain pump is
switched on for 120 seconds.
Cause
Internal technical defect of the power electronic (ELP).
Remedy
A Replace the power electronic (ELP).
3.26 F 45 Electronic fault (defective flash RAM/ wrong data)
Cause
Internal fault power electronic (ELP).
Remedy
A Refer to the M. No. and check if the correct control electronic (EW) and the
correct power electronic (ELP) are installed.
A With the program function, reset all to the Delivery status. Then program all
necessary settings.
A Replace the power electronic (ELP).