4 Service
4.1 Temperature sensor (NTC resistor, R30)
x
Danger!
Risk of electric shock when working on low-voltage components.
In the power electronic (ELP), there is no galvanic isolation from the power
supply.
When working on a washer connected to the power supply, be aware of the risk
of mains potential on low-voltage components.
4.2 Air trap – Clean
A Remove the front panel, refer to Front panel – Remove, 010 4.2.
4.3 Door sealing ring – Replace
A Remove the front panel, refer to Front panel – Remove, 010 4.2.
x
Fig. 1
A Loosen the hose clip at the sealing ring and remove the hose clip.
A Remove the cap from the lamp, pull the plug off and remove the lamp.
A Pull the nozzle from the connecting hose, press the nozzle out of the sealing
ring.
A Installation: Door sealing ring marker at 9 o'clock.
Descriptive Technical Documentation
DTD no. 11-4800 030-5
22.12.2006, US_am This information should not be duplicated or passed on without Miele approval. All rights reserved.