the fault message Check dosage is issued at program end,
the fault message F 16 excess foam dosage is saved, refer to F 16
Oversudsing, 070 3.17.
2.2 Light in the door concer tina seal
LED lamp in the concertina seal.
2.3 Heater
Thermal cut-out:
To protect the appliance from overheating in the case of a technical malfunction,
e. g. if a heater relay is stuck, the heater element is equipped with an integrated
thermal cut-out.
If the thermal cut-out trips, the heater element is destroyed.
Descriptive Technical Documentation
030-4 DTD no. 11-4800
This information should not be duplicated or passed on without Miele approval. All rights reserved. 22.12.2006, US_am