3. if necessary, wait until the water has
cooled down;
4. open the pump door;
5. place a container on the floor below the
recess of the drain pump;
6. press the two levers and pull forward
the drainage duct to let the water flow
out;
7. when the container is full of water, put
the drainage duct back again and empty
the container;
repeat this operation until water stops
flowing out;
8. if necessary clean the pump (refer to
the section ‘Drain pump’ );
9. close the drain pump door.
When you drain the water with the
emergency drain procedure, you must
activate again the drain system:
1. Put 2 litres of water in the main wash
compartment of the detergent
dispenser.
2. Start the programme to drain the
water.
Frost precautions
If the machine is installed in a place where
the temperature could drop below 0°C,
remove the remaining water from the inlet
hose and the drain pump.
1. disconnect the mains plug from the
mains socket.
2. close the water tap
3. unscrew the water inlet hose from the
tap;
4. put the two ends of the inlet hose in a
container and let the water flow out of
the hose.
5. empty the drain pump as described in
the ‘Emergency drain’ section.
6. when the drain pump is empty, install
the water inlet hose again.
Warning!
Make sure that the temperature is more
than 0 °C before you use the appliance
again.
The manufacturer is not responsible for
damages caused by low temperatures.
28