• The appliance makes an unusual noise
because of the blockage of the drain
pump.
• A problem with water draining is detected
(see chapter “What to do if...” for more
details).
Warning!
1. Disconnect the mains plug from
the mains socket.
2. Do not remove the filter while
the appliance operates. Do not
clean the drain pump if the water
in the appliance is hot. The
water must be cold before you
clean the drain pump.
To clean the drain pump:
1. Open the pump door.
2. Put a container below the recess of the
drain pump to collect the water that
flows out.
3. Press the two levers and pull forward
the drainage duct to let the water flow
out.
4. When the container is full of water, put
the drainage duct back again and empty
the container. Do steps 3 and 4 again
and again until no more water flows out
from the drain pump.
5. Pull back the drainage duct.
6. Unscrew the filter and remove it.
1
2
7. Remove fluff and objects from the
pump.
8. Make sure that the impeller of the pump
can turn. If this does not occur, contact
the service centre.
26