15
17. MALFUNCTION CODE
OF OUTDOOR UNIT
Display Malfunction or Protection
E0 EEPROM malfunction
E2 Communication malfunction between
indoor/outdoor units
E3 Communication malfunction between
DSP/outdoor units
E4 T4 temperature sensor
malfunction
E5 Compressor Voltage protection
P0 Compressor Top Temperature
Protection
P1 High Pressure Protection
P2 Low Pressure Protection
P3 Compressor current protection
P4 Compressor discharge temperature
protection
P5 Protección de alta temperatura
P6 Module protection
CAUTION
Please cut off the power supply when appearing
the above malfunction, check the voltage provided
is out of range, check if the installation of air-
conditioner is correct, then electrify again after 3
minutes power off. If the problemis still existent,
please contact the local service station or the
equipment provider.
Air Conditioner DC Duct Type
EN