Air Conditioner DC Duct Type
EN
The Specification of Power
Outdoor unit power
Weak electric signal
18000 Btu/h
1-Phase
220-240V - 50 Hz
30/25
3 x 1,0
3 x 2,5
3 core shield wire
24000 Btu/h
1-Phase
220-240V - 50 Hz
40/25
3 x 1.0
3 x 2,5
3 core shield wire
36000-60000 Btu/h
3-Phase
380-415V - 50 Hz
40/25
3 x 1,0
5 x 2,5
3 core shield wire
Phase
Frequency and volt
Type
Power
Circuit breaker / Fuse (A)
Indoor/Outdoor
connecting wiring
(mm )
Indoor unit power wiring(mm )
2
2
CAUTION
NOTE
The reserved function is indicated in broken line
table,users can select it when necessary
Terminal Board Diagram
Please refer to the indoor unit wiring diagramfor
the wiring.
The air-conditioners can connect with Central
Control Monitor (CCM). Before operation,
please wiring correctly and set system address
and network address of indoor units.
CAUTION
The reserved function is indicated in broken line table,users can select it when necessary
CONTROL
As per the different usages to set the moving
switch on the PCB in the electric control box of
indoor unit.
After the setting , be sure to cut down the main
power supply switch, then turn it on again
Setting would be invalid without disconnecting the
power.
Please number the indoor units during the
installation. For example, for the first outdoor unit
,the number of the first indoor unit is 1-1, the
second indoor unit is 1-2, and the set address is
1 and 2 respectively, the others is analogical.
Model 1 show the address
'0-F' respectively,
that is, '0-15' indoor unit
Model 2 show the address
'0-F' respectively,
that is, '16-31' indoor unit