Dil ID: 11
Dil Adı: russia
Dil Kodu: ru1tayfun Продукция бренда Zanussi
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



Problem Possible solution
Make sure that the pressure of the water supply is not too
low. For this information, contact your local water authority.
Make sure that the water tap is not clogged.
Make sure that the filter in the inlet hose is not clogged.
Make sure that the inlet hose has no kinks or bends.
The appliance does not drain the water. Make sure that the sink spigot is not clogged.
Make sure that the drain hose has no kinks or bends.
The anti-flood device is on. Close the water tap and contact the Service.
After the checks are completed, turn the pro-
gramme knob until the programme marker is
aligned with programme that was in operation
when the problem occurred. The programme
continues from the point of interruption.
If the problem occurs again, contact the Serv-
ice.
If other alarm codes show, contact the Service.
If the washing and drying results are not
satisfactory
Whitish streaks or bluish layers on
glasses and dishes
The released quantity of rinse aid is too
much. Adjust the rinse aid selector to a lower
position.
The quantity of detergent is too much.
Stains and dry water drops on glasses
and dishes
The released quantity of rinse aid is not suffi-
cient. Adjust the rinse aid selector to a higher
position.
The quality of the detergent can be the
cause.
Dishes are wet
The programme is without a drying phase or
with a low temperature drying phase.
The rinse aid dispenser is empty.
The quality of the rinse aid can be the cause.
Refer to ‘HINTS AND TIPS’ for other pos-
sible causes.
Technical information
Dimensions Width / Height / Depth (mm) 446 / 850 / 605
Electrical connection Refer to the rating plate.
Voltage 220-240 V
Frequency 50 Hz
Water supply pressure Min. / max. (bar / MPa) (0.5 / 0.05 ) / (8 / 0.8 )
Water supply
1)
Cold water or hot water
2)
max. 60 °C
Capacity Place settings 9
Power consumption Left-on mode 0.99 W
Off-mode 0.10 W
1) Connect the water inlet hose to a water tap with a 3/4'' thread.
2) If the hot water comes from alternative sources of energy, (e.g. solar panels, aeolian energy), use the hot
water supply to decrease energy consumption.
12
www.zanussi.com