Prestige 661H/HW Series User’s Guide
Appendix M Internal SPTGEN 512
APPENDIX M
Internal SPTGEN
Internal SPTGEN Overview
Internal SPTGEN (System Parameter Table Generator) is a configuration text file useful for
efficient configuration of multiple Prestiges. Internal SPTGEN lets you configure, save and
upload multiple menus at the same time using just one configuration text file – eliminating the
need to navigate and configure individual SMT menus for each Prestige.
The Configuration Text File Format
All Internal SPTGEN text files conform to the following format:
<field identification number = field name = parameter values
allowed = input>,
where <input> is your input conforming to <parameter values allowed>.
The figure shown next is an example of an Internal SPTGEN text file.
Figure 316 Configuration Text File Format: Column Descriptions
Note: DO NOT alter or delete any field except parameters in the Input column.
For more text file examples, refer to the Example Internal SPTGEN Screens Appendix.
Internal SPTGEN File Modification - Important Points to Remember
Each parameter you enter must be preceded by one “=”sign and one space.
/ Menu 1 General Setup
10000000 = Configured <0(No)| 1(Yes)> = 1
10000001 = System Name <Str> = Prestige
10000002 = Location <Str> =
10000003 = Contact Person’s Name <Str> =
10000004 = Route IP <0(No)| 1(Yes)> = 1
10000005 = Route IPX <0(No)| 1(Yes)> = 0
10000006 = Bridge <0(No)| 1(Yes)> = 0