Dil ID: 13
Dil Adı: romaina
Dil Kodu: ro5tayfun Produsele mărcii Visonic
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



8 D-302754 PowerMaxComplete Installer's Guide
Antenna cable
Internal
GSM
antenna
Connector
Figure 3.6 - GSM Internal Antenna Mounting
3.8 DUAL RS-232 Optional Module
Mounting
The DUAL RS-232 is a Module that enables connection of
any two simultaneous devices, such as Local PC
programming or GSM Module.
The internal GSM unit enables the PowerMaxComplete
system to operate over a cellular network (for details
regarding the GSM modem features and connections,
refer to the GSM Modem installation instructions).
To install the DUAL RS-232 module into the control panel,
press it into the marked location (see drawing below) until
a click is heard.
Connect a local PC or GSM module, to one of the DUAL
RS-232 module connectors, as shown below.
Connector for PC
Connector for external
GSM or PC
DUAL RS-232 MODULE
Figure 3.8 – DUAL RS-232 Module Mounting
3.9 Optional Expander Module
Mounting
The EXPANDER module enables connection of speech
box, site external siren, site internal siren or strobe and
connection of wired detector to zone number 29 and 30.
The EXPANDER module also enables connection of a
desired device to PGM (programmable) output that is
activated according to predefined conditions.
Mount the Expander module as shown below.
2 Clips
Co n n e c t th e
E x p a n d e r
M o d u l e f l a t
cable to the front
p a n e l
E X PA N D E R
receptacle.
The receptacle
with strain relie
f
clip is for the
front unit - do not
connect to the
back unit!
Strain relief clip
2
1
P r e s s t h e
E X P A N D E R
module in the back
panel between its
2 clips.
Figure 3.9 – EXPANDER Module Mounting
3.10 Power Cable Connection
Connect the power cable and close the control panel as
shown in figure 3.10.
Socket-outlet shall be installed near the equipment and
shall be easily accessible.