Dil ID: 13
Dil Adı: romaina
Dil Kodu: ro3tayfun Produsele mărcii Kenmore
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



MI m №i{R Fiine.., (M
Nisnidiuu
SYSTEM SPECIFICATION AND PERFORMANCE DATA
SHEET REFRIGERATOR WATER FILTER CARTRIDGE
MODEL 9005
Specifications
Service Flow Rate (maximum).........................................................0.75 GPM (2.83 Limin)
Rated Service Life Model 9005 (maximum)
....................................
500 gallons/1892 liters
Maximum Operating Temperature...................................................100° F/38° C
Minimum Operating Temperature....................................................33° F/1° C
Minimum Pressure Requirement
.....................................................
35 psi/138 kPa
Maximum Operating Pressure.........................................................120 psi/827 kPa
PERFORMANCE DATA
Substance
Influent Challenge
Concentration
Effluent
Average
Average %
Reduction
Maximum
Effluent
Min. Required
Reduction
Inlet
pH
Lead
0.15 mg/L+/-10%
0.001 mg/L
99.33%
0.001 mg/L
0.010 mg/L 6.5
Lead
0.15mg/L+/-10%
0.002 mg/L
98.66%
0.003 mg/L
0,010 mg/L
8.5
Cyst
Minimum 50,000/L
Icount/mL
99.99% 3 count/mL
> 99.95% NA
Turbidity
11+/-1 NTU
0.12 NTU
98.98%
0.18 NTU
0.5 NTU
NA
Lindane
0.002 mg/L +/-10%
0.00005 mg/L
97.62%
0.00005 mg/L
0.00002 mg/L
NA
Atrazine
0.009 mg/L +/-10%
0.0002 mg/L 97.93%
0.0006 mg/L
0.003 mg/L NA
Chlorine
2.0 mg/L+/-10%
0.09 mg/L
95.26%
0.17 mg/L
г75%
NA
Particulate**
at least 10,000
particles/mL
900 count/mL
99.68%
2400 count/mL
285%
NA
2,4-D
0.210 mg/L +!-10%
45,45 ug/L 84.42%
100 ug/L
0.0017 mg/L NA
Asbestos
10' to 10" fibers/L; fibers greater
than 10 micrometers in length
0.16 MFL/mL
99.96%
0.16 MFL/mL
99%
NA
* Tested using a flow rate of 0,75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa)
under standard laboratory conditions, however, actual performance may vary. Health Claim
Performance tested and certified by NSF International
** Particle size range classification of test. Particles used were 0.5 -1 microns.
Stale of California
Depanment of Health Services
Water Treatment Device
Certificate Number
01 - 1486
Date Issued; September 21, 2001
Date RevUed: March 20,2002
Tbademark/Model Designation
WF50-WI500
WF50-NI300
WF50-KW15Ü0
WF50-KNB00
OWF50-WÍ500 ■■
OWF50-NI300 ^
Manufacturer; РеШлРиге tneocporaied
GENERAL USE
CONDITIONS
Read this Performance Data Sheet and
compare the capabilities of this
refrigerator with your actual water
treatment needs.
DO NOT use this product where water
is microbioiogicaiiy unsafe or of
unknown quaiity without adequate
disinfection installed before or after
filtration system. Systems certified
for cyst reduction may be used on
disinfected water that may contain
filterable cysts.
Use only with cold water supply.
Check for compliance with the state
and local laws and regulations.
The retractable water filtration system
uses a 9005 replacement cartridge (see
Sears contact information at the back of
your Use and Care Guide to order).
Timely replacement of filter cartridge is
essential for performance satisfaction
from this filtration system. Please refer
to the applicable section in this Use and
Care Guide for general operation,
maintenance requirements and
troubleshooting.
This system has been tested according
to ANSI/NSF 42 and 53 for reduction of
the substances listed below. The
concentration of the indicated
substances in water entering the system
was reduced to a concentration less than
or equal to the permissible limit for water
leaving the system, as specified in
ANSI/NSF 42 and 53.
WF5Û ,
WF5Ö ■
: 46 9005,.
46 9005 '
OWF5I
OWF5I
500 gal
300 gal
Thi: waler treatmeol devicets) list*donlhi.5,certiiicate have met the testing rtQuitEmenls pursuant to Section 116830 of the
Health and Safety Code for the foUowiag health related contaminants;
Microbiological Conlaminatasnnd 'ПлЫДИу
iBOgamc/Radiotneical Contaminante
Asbesss
Tested and certified by NSF International against ANSI/NSF Standards 42 and 53 in
models WF50-KNI300 and WF50-KWI500 for the reduction of:
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane and 2, 4-D Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction
tí)
PerrtaPure
1000 Apollo Road
Eagan, Minnesota U.S.A.
EPA EST #35917-MN-1
Rated Service Flow: 0.7S
14