Dil ID: 13
Dil Adı: romaina
Dil Kodu: ro10tayfun Produsele mărcii DCS
Dünyanın En Büyük
Elektronik Bilgi Kütüphanesi



SAMSUNG DCS PROGRAMMING
TECHNICAL MANUAL December 1996
MMC: 800 ENABLE TECHNICIAN PROGRAM
DESCRIPTION:
Used to open and close technician level programming. If programming is not opened and an
attempt is made to access a system MMC, the error message ACCESS DENIED will be
displayed.
A four digit passcode is required to access this MMC. Each character can be digits 09 or .
When opened, this MMC enables access to all MMCs.
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor left and right
SPK Used to store data and advance to next MMC
ACTION DISPLAY
1. Press TRSF 800
Display shows
ENABLE TECH.PROG
PASSCODE:
2. Enter passcode
Correct code shows
Incorrect code shows
ENABLE TECH.PROG
PASSCODE:4321
ENABLE TECH.PROG
DISABLE TENANT:1
ENABLE TECH. PROG
PASSCODE ERROR
3. Press UP or DOWN to open or close
OR
Enter 1 to enable or enter 0 to disable, press RIGHT soft
key to move to tenant number and enter tenant number
(1 ~ 2)
ENABLE TECH.PROG
ENABLE TENANT:1
ENABLE TECH.PROG
ENABLE TENANT:1
4. Press SPK to advance to MMC entry level 801:TEC.PASSCODE
SELECT PROG.ID
5. Enter the MMC desired (e.g., 209) 209:AOM MASTER
AOM NOT EXIST
6. To log out and return to MMC 800 ,press UP or DOWN
key to select DISABLE TENANT:1
OR
Press SPK then TRSF to return to normal display
Programming option will time out
DEFAULT DATA: NONE
RELATED ITEMS: MMC 801 CHANGE TECHNICIAN PASSCODE