Inlet connection: ½” FPT or 1” FPT
Water supply line must be at least ½” service.
Incoming water pressure must be greater than 35 psi.
Drain Line connection: 3/8” Tubing or
¼” FTP, ½” FPT
Permeate: ¼” OD Plastic Tubing
Maximum Recovery rate: 1:1
Electrical: 110v/7.2 amps/60Hz (15-amp service)
220v/4.3amps/60Hz (10-amp service)
Electrical supply outlet must be with in 8’ of WM-
control box.
Mounting weights: of WM -Module with:
10” filter housing 135-lbs. wet
20” filters housing 175-lbs. wet
WM -Control Box: 8-lbs.
5.0 Equipment location:
The drawing in the front of the manual is to be
used as a general reference guideline for placement
of any pre & post treatment equipment that you
may have.
5.1 WM-Module: To be mounted to a flat wall
surface. WM -Module should be located and mounted
in a location that allows for easy access for future
servicing of pre-filter.
5.2 WM-Control Box: To be mounted within 5 ft of
WM -Module for the connection of the electrical.
Note: The WM-Control Box should not be located
directly below the WM -Module. See Section 7.0 for
more details.
5.3 Pre-Treatment: Depending on the incoming feed
water chemistry, additional pre-treatment may be
needed to address specific water chemistry and to
protect the WM -membranes. Placement of other pre-
treatment equipment should allow for future access to
the WM -pre-filter. Installation of any additional pre-
treatment equipment to be done in accordance, with
it’s own manual.
5.4 Post-Treatment: Depending on application, all or
some of post-treatment may be needed and the
location may vary from the general layout. All post-
treatment equipment should be installed accordance to
it’s own manual.
6.0 Mounting WM-Module:
Locate and mount WM-Module before making any
connection. Premier Manufactured Systems, Inc
assumes no responsibility or liability in mounting
WM-Module to a wall. Use the following as a
guideline only.
Warning: The WM-Module must be firmly secured
to a wall that can support the weight of the WM-
unit during operation.
The mounting bracket of the WM-Module has (3)
slotted keyholes for mounting the WM-Module to
the wall. The head of the screws or bolts should be
of a size that can pass through the larger part of
the slotted keyhole but not the smaller slotted area
that it will slide into.
WM-Module should be anchored and mounted to a
wall according to local building codes.
6.1 Anchoring WM-Module to Block or concrete
walls:
Molly bolt or anchoring insert devices should be used
on all brick, concrete block, or concrete walls.
Anchoring devices should be installed according to the
manufacturer instructions.
6.2 Anchoring WM-Module to Sheet-rock walls:
The (2) outside mounting Slotted Keyholes on the
WM -Module bracket are on 16” centers to allow
anchoring into wall studs that are on 16” centers.
6.4 If wall studs are not on 16” centers, or the location
of the WM does not allow it be anchored into wall
studs, an additional support brace may be required.
Support brace should be at least 1” thick by 6” wide
and no less than 24 inches in length. Support braces
must be secured into the at least (2) wall studs. The
brace may be glued and additional screws used to
ensure a solid mounting surface for the WM -module
as shown below.
7.0 Mounting WM-Control Box:
7.1 The WM -Control box should be located off to the
side or above the WM -Module. Do not install the
WM -Control box below the WM -Module. Water may
spill out of the filter-housing sump during filter
changes.
7.2 WM -Control box must be mounted within 5 ft. of
the WM -Module, for connection of electrical wires to
the WM -module. The WM -control box come with an
8-ft power cord and require electrical outlet within 8-
ft.