Replace the front grill and reconnect the unit to power. Failure to clean the condenser
coil can lead to performance loss and compressor failure.
TROUBLESHOOTING
Problem Remedy
Compressor will
not start
· Check the power cord and make sure it is plugged in and has
power.
· Check the temperature controller. If it is in the “OFF” position,
turn it clockwise to set a desired temperature.
Poor
performance
· Move the unit from direct sunlight.
· Move the unit away from heating devices.
· Install the unit in a well ventilated place,
with at least 2 inches of clearance on all sides.
· Clean the condenser if heavy dust is collected.
· Clear contents from blocking the inside air duct.
· Check the temperature controller for correct setting.
· Check the covers and be sure they are completely closed.
Unit noisy
· Install the unit on a level solid surface.
· Maintain 2 inches of clearance from the wall.
· Check for loose parts or mounting.
· Keep the tubing free from any contact to avoid rattle.
Condensation on
cabinet exterior
and/or floor
· Reduce humidity where the unit is installed.
·
Check the drain line to make sure it is not disconnected inside the
cabinet and it drains into the drain pan in the compressor area.